HUAWEI TR069

HUAWEI TR069

HUAWEI TR069 – can be sent in the description below:
First under Access Profile Management > Tr069 Server Profile we need to create a TR069 prifile(After creating the profile right click on the Profile that is created and “Download to NE…”):

U2000 TR069

U2000 TR069

Second on the ONT right click > Modify > TR069 SERVER PROFILE > Drinia > OK

Apply tr069 into U2000

Apply tr069 into U2000

This way is applied TR069 Server into ONT.

Another way to do it is to use Telnet:

To set the URL Link of the TR069 Server into the specific ONT
ont tr069-server-config 0 3 profile-id 20

To set TR069 Server into every ONT that is connected to specific PON Port:
ont tr069-server-config 0 all profile-id 20

Another way to do it is to use SNMP:
1.3.6.1.4.1.2011.6.145.1.1.1.13.1.3.{PortID}.{ONTID}: “Drinia”